MINERAL WOOL BOARD:
FlameGuard MWB
 Fire Retardant Mineral Wool Board:
FlameGuard MWB is a fire & heat resistant mineral wool boards coated on both sides with FlameGuard CP intumescent coating, affixed with FlameGuard EFM expanding sealant, to prevent the passage of fire and smoke and the transfer of heat. Final aesthetic protective top coating of FlameGuard FRP for moisture protection. It is specifically designed for sealing around cable & service penetrations in walls and floors.

Dimension:
Outer Boards – 2 x 595mm x 1195mm x 23mm (Each Board 0.71 Sq mtrs). Size subject to change. Infill Rockwool Insulation pre – coated with FlameGuard Intumescent coatings > 1mm DFT – 4x 1mtr x 0.50mtr x 50mm (0.50 sq mtr each infill insulation panel).
FlameGuard EIC
High performance epoxy intumescent fire protection coating system
The product is a high build, two pack material providing excellent durability combined with excellent corrosion and fire protection for a long period of time for structures, pipe work, vessels and fire resistant divisions from the effects of hydrocarbon pool and jet fires caused due to petrol, diesel, petrochemicals and gases, cellulosic fire etc., primarily intended for use in high risk environments such as oil, gas, petrochemical and power generation industries. Suitable for both offshore and onshore environments. The coating thickness required for protection is normally specified in the range of 4-20 mm. To be used as mid coat as part of a complete system in atmospheric environments followed by weather resistant aliphatic polyurethane finish coat, MonoGuard PCG. The coating facilitates as sealer function to prevent early degradation and inactivation of intumescent layer. Depending on the actual exposure of the coating system, various primers and topcoats can be used in combination with this product.
Base Coat  - FlameGuad ZP - Primer
Intermediate / Mid Coat - FlameGuard EIC
Top Coat - MonoGuard PCG - Aliphatic Polyurethane top coat
Applications::
Floating Production Storage & Off-shore loading Vessels (FPSO) Refineries
Petrochemical plants
Liquified Natural Gas (LNG) terminals
Liquified Petroleum Gas (LPG) storage facilities

BUILDING INTERIOR & EXTERIOR PROTECTION:
FlameGuard FRP:
Fire Resistive/Retardant Paints to delay ignition/surface burning for Interior & Exterior Substrates
FlameGuard FRP is premium quality water based, nontoxic thin film fire retardant paint formulated to delay ignition for 10-15 minutes and reduce surface burning rate of interior substrates, including gypsum board, composite architectural panels, oriented strand board and other wood products. This product is suitable for residential/multifamily, commercial for both new and reconstruction projects
Coverage: 10 Sq.m/ 5 Kg @ 250 Mic DFT

 Structural steel protection:

FlameGuard ZP - Primer:
Epoxy based zinc rich primer for fire protection coating for structural steel.To protect steel against corrosion & prepare the surface.
Coverage: 21 Sq.m/ 4 kgs / @ DFT 125 microns
FlameGuard SSP - Base Coat:
During fire when the structural steel temperature approaches 538°C it lose 60% of its yield strength and may lead to the building collapse. FlameGuard SSP Base Coat – coated to desired thickness prevents steel structures from crossing the critical temperature of 538°C, thus delaying the collapse of loaded steel structures for up to 2 hours and providing time for evacuation & fire fighting. The smooth fibre free robust decorative surface allows the architect to use the structural steel work as an integral part of the building design. Rapid installation with typically DFT's below 2mm, appearance of the structure is preserved without affecting the load bearing calculations. In case of fire, the film expands to many times its original film thickness.This provides an insulating foam-like coating or char to protect steelwork against heat build-up and the effects of fire.
Coverage: F 30 - 8 Sq.m / 5 kgs @ DFT 320 microns

FlameGuard SSP - Top Coat:
Thin film high solids intumescent coating provide maximum protection & enables a high quality finish to be obtained similar to conventional decorative paints. A hard decorative self-extinguishing, fast drying finish to seal the basecoat & provide an attractive high quality finish. Recommended as a top coat over FlameGuard SSP Base Coat for optical reasons and moisture protection. The coating facilitates as sealer function to prevent early degradation and inactivation of intumescent layer. Available in various RAL shades.
Coverage: F 30 - 15 Sq.m/ 5 kgs @ DFT 180 microns
Coverage::F30 - 925 gms / Sq.m (DFT 500 microns). F60 - 1850 gms / Sq.m (DFT 1000 microns).
F90 - 2400 gms / Sq.m (DFT 1300 microns). F120 - 3330 gms /Sq.m (DFT1800 microns)
Applications::
I Sections
Hollow Sections
Universal Sections
Cellular Beams & Columns Exposed Steel Membranes Angles, Channels, Truss, Tubes Wall assemblies,
Floor/ceiling assemblies Roof/ceiling assemblies Structural Steel
Kitchens

Hollow Sections
Universal Sections
Cellular Beams & Columns Exposed Steel Membranes Angles, Channels, Truss, Tubes Wall assemblies,
Floor/ceiling assemblies Roof/ceiling assemblies Structural Steel
Kitchens