Showing posts with label fire retardant paint. Show all posts
Showing posts with label fire retardant paint. Show all posts

FlameGuard MWB

FlameGuard MWB is a fire & heat resistant mineral wool boards coated on both sides with FlameGuard CP intumescent coating, affixed with FlameGuard EFM expanding sealant, to prevent the passage of fire and smoke and the transfer of heat.

fire resistant coating for cables:

FlameGuard CP

FlameGuard CP is a water-based intumescent coating which is designed to prevent ignition, flame spread & smoke emission along the jacketing of electrical (or other) cables and to provide a thermal barrier for protection against heat damage. FlameGuard CP will also prevent a short circuit within an electrical cable from starting a fire and will help identify the location of such a short circuit by forming an intumescent char at the spot.

FlameGuard CP


MINERAL WOOL BOARD:
FlameGuard MWB
 Fire Retardant Mineral Wool Board:
FlameGuard MWB is a fire & heat resistant mineral wool boards coated on both sides with FlameGuard CP intumescent coating, affixed with FlameGuard EFM expanding sealant, to prevent the passage of fire and smoke and the transfer of heat. Final aesthetic protective top coating of FlameGuard FRP for moisture protection. It is specifically designed for sealing around cable & service penetrations in walls and floors.

Dimension:
Outer Boards – 2 x 595mm x 1195mm x 23mm (Each Board 0.71 Sq mtrs). Size subject to change. Infill Rockwool Insulation pre – coated with FlameGuard Intumescent coatings > 1mm DFT – 4x 1mtr x 0.50mtr x 50mm (0.50 sq mtr each infill insulation panel).
FlameGuard EIC
High performance epoxy intumescent fire protection coating system
The product is a high build, two pack material providing excellent durability combined with excellent corrosion and fire protection for a long period of time for structures, pipe work, vessels and fire resistant divisions from the effects of hydrocarbon pool and jet fires caused due to petrol, diesel, petrochemicals and gases, cellulosic fire etc., primarily intended for use in high risk environments such as oil, gas, petrochemical and power generation industries. Suitable for both offshore and onshore environments. The coating thickness required for protection is normally specified in the range of 4-20 mm. To be used as mid coat as part of a complete system in atmospheric environments followed by weather resistant aliphatic polyurethane finish coat, MonoGuard PCG. The coating facilitates as sealer function to prevent early degradation and inactivation of intumescent layer. Depending on the actual exposure of the coating system, various primers and topcoats can be used in combination with this product.
Base Coat  - FlameGuad ZP - Primer
Intermediate / Mid Coat - FlameGuard EIC
Top Coat - MonoGuard PCG - Aliphatic Polyurethane top coat
Applications::
Floating Production Storage & Off-shore loading Vessels (FPSO) Refineries
Petrochemical plants
Liquified Natural Gas (LNG) terminals
Liquified Petroleum Gas (LPG) storage facilities

 Structural steel protection:

FlameGuard ZP - Primer:
Epoxy based zinc rich primer for fire protection coating for structural steel.To protect steel against corrosion & prepare the surface.
Coverage: 21 Sq.m/ 4 kgs / @ DFT 125 microns
FlameGuard SSP - Base Coat:
During fire when the structural steel temperature approaches 538°C it lose 60% of its yield strength and may lead to the building collapse. FlameGuard SSP Base Coat – coated to desired thickness prevents steel structures from crossing the critical temperature of 538°C, thus delaying the collapse of loaded steel structures for up to 2 hours and providing time for evacuation & fire fighting. The smooth fibre free robust decorative surface allows the architect to use the structural steel work as an integral part of the building design. Rapid installation with typically DFT's below 2mm, appearance of the structure is preserved without affecting the load bearing calculations. In case of fire, the film expands to many times its original film thickness.This provides an insulating foam-like coating or char to protect steelwork against heat build-up and the effects of fire.
Coverage: F 30 - 8 Sq.m / 5 kgs @ DFT 320 microns

FlameGuard SSP - Top Coat:
Thin film high solids intumescent coating provide maximum protection & enables a high quality finish to be obtained similar to conventional decorative paints. A hard decorative self-extinguishing, fast drying finish to seal the basecoat & provide an attractive high quality finish. Recommended as a top coat over FlameGuard SSP Base Coat for optical reasons and moisture protection. The coating facilitates as sealer function to prevent early degradation and inactivation of intumescent layer. Available in various RAL shades.
Coverage: F 30 - 15 Sq.m/ 5 kgs @ DFT 180 microns
Coverage::F30 - 925 gms / Sq.m (DFT 500 microns). F60 - 1850 gms / Sq.m (DFT 1000 microns).
F90 - 2400 gms / Sq.m (DFT 1300 microns). F120 - 3330 gms /Sq.m (DFT1800 microns)
Applications::
I Sections
Hollow Sections
Universal Sections
Cellular Beams & Columns Exposed Steel Membranes Angles, Channels, Truss, Tubes Wall assemblies,
Floor/ceiling assemblies Roof/ceiling assemblies Structural Steel
Kitchens

Hollow Sections
Universal Sections
Cellular Beams & Columns Exposed Steel Membranes Angles, Channels, Truss, Tubes Wall assemblies,
Floor/ceiling assemblies Roof/ceiling assemblies Structural Steel
Kitchens
FlameGuard CP
Intumescent fire protection coating for combustible single & bunched electrical cables
and cable trays

Long runs of unprotected, PVC or plastic rubber sheathed combustible cables, usually supported by vertical or horizontal cable trays and holders, are prone to rapid fire spread and excessive damage. Unprotected cables burn & propagate fire after only a few minutes of exposure to fire. Power current for vital control functions, supplies and services fails very quickly. Burning cable sheaths carry the fire rapidly forward as fast as 20 meters per minute. They gives off aggressive vapors. The cable trays, if not protected, are exposed to the risk from melting and collapsing. Cables, cable trays and holders protected with FlameGuard CP help prevent damage or keep it within reasonable limits.The time that elapses before the current fails is increased many times. The indirect damage from cable fires (fire travel, breakdowns, corrosion resulting from harmful gases affecting sensitive instruments) is generally greater than the
f ire damageinitially visible.
FlameGuard CP is a water-based intumescent coating which is designed to prevent ignition, flame spread & smoke emission along the jacketing of electrical (or other) cables and to provide a thermal barrier for protection against heat damage. FlameGuard CP will also prevent a short circuit within an electrical cable from starting a fire and will help identify the location of such a short circuit by forming an intumescent char at the spot. The coating can be applied to grouped cables or single cables.When exposed to flame or to a temperature above 175ºC, the coating forms a protective intumescent char. (This char should be removed completely and clean cables should be recoated if intumescences should occur). The coating foams up under the effect of heat to form an insulating layer.There is no sub sequent burning of protected cables after the direct effect of fire has been halted. 
The thermal conductivity of a FlameGuard CP coating that has not foamed is about the same as that of a plastic cable sheath, which means that the higher temperature of the conductor is raised only insignificantly in cables protected with FlameGuard CP. As only a relatively thin coating is needed, it allows radiation of heat from cables during operation. The current-carrying capacity remains virtually unchanged. The cured coating is flexible and adapts to the usual movements and bending without flaking. Its premium latex binder system is totally resistant to water and will not re-emulsify after drying. FlameGuard CP reduces the spread of flame in cable runs and prevents the emission of hydrochloric gases in cable fires. The release of hydrochloric acids vapors is slowed down considerably.Acid vapors that are released are neutralized.The upgradation of existing cables to the highest grade of f ire safety is possible with the coating of FlameGuard CP. Additionally the thin film coatings will maintain circuit integrity to small diametrical cables in restricted applications. The coating of the entire length of cables to maintain the power supply to important equipment while data are being saved or a fire extinguished (recommended dry film thickness 1.6 mm). Partial coating of cables (4 m length @ every 10 m interval, recommended dry film thickness of 1.6 mm) to prevent f ire from spreading along cable runs.The cable joints and around cable crossing should be coated at 1.5meteronboth sides of joints. 
Coverage: Single Cable - 1.75 Sq.m / 5 Kg @DFT 1.5 mm Thickness
Grouped /Bunched /Jacketed Cables - 1.43 Sq.m / 5 Kg @DFT 2 mm Thickness 

Applications:
Electric Power Cables
Communication Cables
Fiber Optic Cables
Control Cables
Cable Conduits
Instrumentation Cables
Junction / Crossings of Cable routes
Switch gears
Cable Trays
Racked Cables
High Rise Buildings
High Security Buildings